Network (LAN) cable

Network cable FTP cat. 5E 4x2x24AWG solid
4 bare copper (BC) twisted pairs
Polyester tape/Aluminium foil shield
Tinned copper drain wire with diameter 0.40 mm (26 AWG)
HDPE insulation PVC sheath



Application:

For installation in local area networks (LAN) with maximum data transmission speed up to 100/1000 Mbps (1 Gbps), in CCTV networks and systems.

Technical characteristics:

  • Produced according to ANSI/TIA/EIA-568-B, IEC 61156-5, ISO/IEC 11801, EN 50173
  • Conductor resistance at DC and temperature 20 °C: 28.6 Ohm/1000 feet (9.38 Ohm/100 m.), max.
  • Resistance unbalance: 2%, max.
  • Impedane: 100 Ohm +/- 15 Ohm
  • Dielectric strength: 2500 V DC (conductor-conductor)
  • Insulation resistance: 150 Ohm/km, min.
  • Mutual Capacitance: 5600 pF/100 m., max.
  • Capacitance unbalance: 330 pF/100 m., max.
  • Delay skew: 11 ns/100 m., max.
  • Velocity of propagation: 67%
  • Maximum pulling force during installation: 80 N, max.
  • Tensile strength: 1.68 kg/mm2, min.
  • Elongation: 300%, min.
  • Operating temperature: from -20 °C to +75 °C
  • Flame retardance: acc. to IEC 60332-1
  • Fire load: 400 MJ/km, max.
  • Test voltage: 2000 V
Cable design:
  • Inner conductor: 4 shielded solid bare copper (BC) twisted pairs, with conductor diameter 0.51 +/- 0.02 mm. (24 AWG)
  • Insulation: HDPE
  • Core colours:
    • 1 pair: White-Blue/Blue
    • 2 pair: White-Orange/Orange
    • 3 pair: White-Green/Green
    • 4 pair: White-Brown/Brown
  • Diameter over insulation: 0.95 mm +/- 0.06 mm
  • Ripcord
  • Polyester tape/Aluminium foil shield
  • Tinned copper drain wire with diameter 0.40 mm (26 AWG)
  • Outer sheath: PVC CMR
  • Sheath colour: Gray
  • Cable outer diameter: 6.2 mm +/- 0.1 mm
Packing and weight:
  • Standard packing: pull-out box 1000 feet /305 m./ with dimensions 42 x 22.5 x 42 cm (L x H x W)
  • Cable weight including packing:
    • 11.7 kg/box 305 ì.

Electrical characteristics
(for BC conductors, at temperature 20 °C):

Frequency, MHz Attenuation, dB/100 m. NEXT pair/pair, dB ACR, dB/100 m. PS NEXT, dB EL-FEXT pair/pair, dB/100 m. PS EL-FEXT pair/pair, dB/100 m. Return Loss, dB
1 2.0 65.3 63.3 63.5 - - 20
4 4.1 56.3 52.2 54.2 - - 23
8 5.8 52.4 46.6 50.5 - - 24.5
10 6.6 51.3 44.7 49.2 - - 25
16 8.2 49.3 41.1 47.4 - - 25
20 9.3 48.8 39.5 46.9 - - 25
25 10.4 45.3 34.9 43.4 - - 24
31.25 11.7 43.0 31.3 41.8 - - 23
62.5 17.0 39.2 22.2 37.2 - - 21
100 22.0 36.3 14.3 34.4 - - 20
155 28.1 35.5 7.4 33.6 - - 19
200 32.4 31.8 - 29.9 - - 19
240 36.0 30.6 - 28.7 - - 18
300 41.0 29.2 - 27.0 - - 18
350 44.9 28.0 - 25.6 - - 17


Please contact us for more information.





Your use of this site is governed by these Terms and Conditions and our Privacy Policy.
Please review them before you use the site.
© Copyright 2003 - 2016. Omex Trade Bulgaria Ltd. All Rights Reserved.